0

Out of 0 Ratings

Owner's of the Bayou Classic Cooktop SP10 gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 36
 
SP10
Bur
ner
14
WARNING
If growing soap bubbles persist throughout any portion of the Gas Leak Test, terminate use immediately.
For assistance, contact your propane dealer or Barbour International, Inc. at 1-800-864-6194.
GAS SUPPLY HOSE
Watch for Bubbles
SP1
Orifice Bar
GAS LEAK TEST INSTRUCTIONS
Note:
The gas leak test must be performed in an area that has
adequate lighting in order to see if bubbles are developing.
DO NOT use a flashlight to check for bubbbles.
1. Create a mixture of 50% water and
50% liquid dishwashing soap.
2. Turn the gas cylinder valve to the OFF position (clockwise).
Then turn regulator valve to OFF position (clockwise).
3. To turn ON the fuel supply, turn the cylinder valve
knob one turn counter-clockwise. Gas will flow through
and stop at the closed regulator valve.
4. Using a clean brush, apply the soap water mixture
to the following:
LP Cylinder welds
Connection Nut to Cylinder Valve
Back side of Connection Nut to Brass Nipple
Brass Valve next to Regulator
Regulator connection to Gas Supply Hose
Gas Supply Hose connection to Burner
Cylinder Valve to Cylinder
Full length of Gas Supply Hose
5. Check each place A - F for growing bubbles which indicates a leak.
6. Next, turn ON regulator valve (counter-clockwise) to permit
gas to pass through the hose. Apply soap water mixture to full
length of gas supply hose and connection to burner assembly.
Check each place for growing bubbles, G & H,
which indicates a leak.
7. Turn OFF gas supply valve (clockwise) on LP Gas Cylinder.
8. Turn regulator valve to OFF position (clockwise).
9. Tighten any leaking connections.
10. Repeat soap water mixture test until no leaks are detected.
DO NOT use cooker if gas leaks cannot be stopped.
Call 1-800-864-6194 M-F 8am - 5pm CST for assistance, or
contact a qualified appliance repair service.
11. After you are certain there are no leaks, turn tank valve and regulator valve to OFF position.