W415-0809 / A / 05.10.10
2.2 GENERAL INFORMATION
CARBON MONOXIDE POISONING MAY LEAD TO DEATH
EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, DIZZINESS
AND/OR NAUSEA. IF YOU HAVE THESE SIGNS, THE APPLIANCE MAY NOT BE WORKING PROPERLY.
GET FRESH AIR AT ONCE! HAVE APPLIANCE SERVICED.
SOME PEOPLE--PREGNANT WOMEN, PERSONS WITH HEART OR LUNG DISEASE, ANEMIA, THOSE
UNDER THE INFLUENCE OF ALCOHOL, THOSE AT HIGH ALTITUDES--ARE MORE AFFECTED BY
CARBON MONOXIDE THAN OTHERS.
THIS APPLIANCE MUST NOT BE INSTALLED IN A BEDROOM OR BATHROOM.
THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.
THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.
!
WARNING
For your satisfaction, this appliance has been test- red to assure its operation and quality!
This appliance is for installation in a solid fuel burning replace or listed ventless rebox enclosures only.
No external electricity (110 volts or 24 volts) is required for
the gas system operation.
This appliance is equipped with a pilot light safety system
referred to as an oxygen depletion sensor (ODS) and is
designed to turn off the appliance if not enough fresh air is
available.
Napoleon’s two vent free rebox enclosures the ZCVF
36/42 can be used to house all 3 of Napoleon’s vent free
log sets, the GVFL 18, 24 and 30.
We suggest that our gas
hearth products be installed
and serviced by profes-
sionals who are certified in
the U.S. by the National
Fireplace Institute
®
(NFI) as
NFI Gas Specialists.
www.nficertified.org
2.3 MINIMUM APPLIANCE SIZE
Each gas log set must be installed into a appliance cavity
with a minimum size.
Refer to the table to determine the appropriate minimum
appliance size.
LOG SET HEIGHT WIDTH DEPTH
GVFL18 18” 22” 14”
GVFL24 20” 28” 14”
GVFL30 22” 34” 14”
GVFL18 GVFL24 GVFL30
NG LP NG LP NG LP
Altitude (FT) 0-4,500 0-4,500 0-4,500 0-4,500 0-4,500 0-4,500
Max input (BTU/HR) 40,000 40,000 40,000 40,000 40,000 40,000
Min Inlet Gas Supply Pressure 4.5“ Water
Column
11“ Water
Column
4.5“ Water
Column
11“ Water
Column
4.5“ Water
Column
11“ Water
Column
Max Inlet Gas Supply Pressure 7“ Water
Column
13“ Water
Column
7“ Water
Column
13“ Water
Column
7“ Water
Column
13“ Water
Column
Manifold Pressure (Under Flow
Conditions)
3.5“ Water
Column
10“ Water
Column
3.5“ Water
Column
10“ Water
Column
3.5“ Water
Column
10“ Water
Column