of 36
 
Turn Coupling Nut
CLOCKWISE
to Attach
Hand Tighten!
Turn Brass Valve
CLOCKWISE
to OFF position
Upright
position
1. Check that cylinder is upright and the valve is closed
by tur
ning the knob clockwise.
2. Remove the protective safety cap from the cylinder valve
and the Type-1 Coupling Nut on the regulator
3. Insert the nipple of the large coupling nut into cylinder valve
outlet. Insure that the coupling nut is centered properly.
4. Turn the large coupling nut clockwise by hand and
tighten to a full stop. Take care not to cross thread
the coupling nut onto the cylinder valve. Do not use
tools to tighten connection.
NOTE: If you are unable to make the connection, repeat steps 3 and 4.
5. Check that the hose does not contain kinks, does not come into contact with sharp edges, and does
not contact surfaces that may become hot during use.
6.
Leak check all fittings before lighting cooker. See section on "Gas Leak Test Instructions" on pages 13 - 14.
WARNING
Insure the cylinder valve is CLOSED (valve turned clockwise) prior to connecting the LP gas cylinder
to your cooker
. Turn brass valve on the regulator clockwise to properly close the flow of gas.
Read and follow all instructions and warnings on the supply hose safety tags. Read and follow all
warnings in this manual concerning the safe use of LP gas cylinders and the regulator hose assembly,
before connecting cylinder to cooker. Read and follow all warnings on the LP gas cylinder.
CONNECTING REGULATOR HOSE ASSEMBLY TO LP GAS CYLINDER
DANGER
LEAK TESTING
T
o prevent fire or explosion hazard:
DO NOT smoke or permit ignition sources in the area while conducting a leak test.
Perform test OUTDOORS only in a well ventilated area at least 10-ft. away from any structure or trees.
Never perform a leak test with a match or open flame.
Never perform a leak test while the cooker is in use or while cooker is still hot.
WARNING
WHEN TO PERFORM A LEAK TEST
After assembling your cooker and before lighting for the first time, even if purchased fully assembled.
Every time the LP gas cylinder is refilled or if any of the gas components are replaced.
Any time your cooker has been moved.
At least once per year or if your cooker has not been used for more than 60 days.
13
GAS LEAK TESTING